A REVIEW OF ENHANCEMENT VOLTAGE PROFILE AND FAULT CURRENT INTERRUPTION USING DVR

Abstract

Power quality is big issue that becoming increasingly issue in industrial electricity in consumer side view.This paper presents about a improvement voltage profile and fault current interruption using DVR.There are different control strategy are available and introduces an auxiliary con- trol strategy for downstream fault current interruption in a radial distribution line by means of a dynamic voltage restorer (DVR). The proposed controller presents the voltage-sag compensa- tion control of the DVR. It does not require phase-locked loop and independently controls the magnitude and phase angle of the in- jected voltage for each phase. Fast least error squares digital fil- ters are used to estimate the magnitude and phase of the measured voltages and effectively reduce the impacts of noise, harmonics, and disturbances on the estimated phasor parameters, and this en- ables effective fault current interrupting even under arcing fault condition.In review there different control strategy are available which are described.

Key Words

Digital filter , Dynamicvoltage restorer,fault current interrupting, Distribution

Cite This Article

"A REVIEW OF ENHANCEMENT VOLTAGE PROFILE AND FAULT CURRENT INTERRUPTION USING DVR", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.1, Issue 7, page no.857-862, December-2014, Available :http://www.jetir.org/papers/JETIR1407051.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"A REVIEW OF ENHANCEMENT VOLTAGE PROFILE AND FAULT CURRENT INTERRUPTION USING DVR", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.1, Issue 7, page no. pp857-862, December-2014, Available at : http://www.jetir.org/papers/JETIR1407051.pdf

Publication Details

Published Paper ID: JETIR1407051
Registration ID: 140451
Published In: Volume 1 | Issue 7 | Year December-2014
DOI (Digital Object Identifier):
Page No: 857-862
Country: PALANPUR, GUJARAT, INDIA .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003180

Print This Page

Current Call For Paper

Jetir RMS