SEISMIC DESIGN OF OPEN GROUND STOREY RC BUILDING

Abstract

Open storey is the storey in which infill wall is absent. Open storey is functionally utilized for the parking purposes in a building. These buildings are not compatible for the earthquake point of view. Because the failure pattern of open storey is quite different from the infill storey. But due some land restraints on us, we have to construct the open storey especially in urban cities. And in such a condition IS 1893:2002 recommends a factor 2.5, which is multiplied to the moments and shear of the beam and column calculated under seismic condition. The objective of the present study is to review the applicability of the multiplication factor. In the present study a G+3 residential building is considered in seismic zone 4 with soft soil condition. Two separate models are prepared, in which one building is considered with an open ground storey and another building in considered with an infill wall. Both static and dynamic analysis is performed. From the result, it is concluded that multiplication factor is recommended by the IS 1893:2002 is ample high.

Key Words

soft storey, weak storey, column interaction, flexure strength, infill masonry

Cite This Article

"SEISMIC DESIGN OF OPEN GROUND STOREY RC BUILDING", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.3, Issue 7, page no.38-41, July-2016, Available :http://www.jetir.org/papers/JETIR1607009.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"SEISMIC DESIGN OF OPEN GROUND STOREY RC BUILDING", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.3, Issue 7, page no. pp38-41, July-2016, Available at : http://www.jetir.org/papers/JETIR1607009.pdf

Publication Details

Published Paper ID: JETIR1607009
Registration ID: 160313
Published In: Volume 3 | Issue 7 | Year July-2016
DOI (Digital Object Identifier):
Page No: 38-41
Country: dehradun, Uttaranchal, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003167

Print This Page

Current Call For Paper

Jetir RMS