UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 3 Issue 10
October-2016
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1610003


Registration ID:
160434

Page Number

14-28

Share This Article


Jetir RMS

Title

Neutral point clamped transformer less grid m connected inverter having voltage buck–boost capability for solar photovoltaic systems

Abstract

This study proposes a neutral point clamped grid-connected transformerless inverter for solar photovoltaic (PV) systems. This inverter has the capability to function in buck–boost mode. Thus the PV voltage level can be chosen to be of lesser value as compared to that of the existing buck type of inverters. This leads to increment in yield of power when PV modules are required to operate under mismatched conditions owing to possibility of more parallel connection of PV modules. Furthermore, buck–boost nature of the proposed inverter also facilitates operation under considerable variation in PV array voltage caused by wide changes in meteorological conditions. The other advantages of the inverter include: (a) elimination of concerns pertaining to the leakage current issues in transformerless grid-connected solar PV systems, (b) elimination of grid current sensor requirement, (c) elimination of shoot-through fault etc. The operating principle of the developed inverter supported by relevant analysis is presented. Control strategy devised for the inverter is provided. Results of detailed simulation studies carried out on MATLAB/Simulink platform are presented to ascertain viability of the proposed scheme. Exhaustive experimental validation has been carried out by utilizing a scaled down laboratory prototype of the proposed inverter.

Key Words

Cite This Article

"Neutral point clamped transformer less grid m connected inverter having voltage buck–boost capability for solar photovoltaic systems", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.3, Issue 10, page no.14-28, October-2016, Available :http://www.jetir.org/papers/JETIR1610003.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Neutral point clamped transformer less grid m connected inverter having voltage buck–boost capability for solar photovoltaic systems", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.3, Issue 10, page no. pp14-28, October-2016, Available at : http://www.jetir.org/papers/JETIR1610003.pdf

Publication Details

Published Paper ID: JETIR1610003
Registration ID: 160434
Published In: Volume 3 | Issue 10 | Year October-2016
DOI (Digital Object Identifier):
Page No: 14-28
Country: --, --, -- .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003131

Print This Page

Current Call For Paper

Jetir RMS