Abstract

This technical paper deals with Major Repairs and Restoration of Elevated Storage Reservoirs (ESR) under Thane Municipal Corporation located at Gandhi Nagar, Thane. Being an old structure, the Elevated Storage Reservoirs faced major problems of structural distress which lead it to undergo Major repairs. Then Thane Municipal Corporation asked M/s. Supreme Engicons(India ) Pvt Ltd., a leading Consulting Civil Engineering firm appointed as Structural Consultant to undertake the Major Repair and Restoration of Elevated Storage Reservoir at Thane. The structure was difficult to get accessed due to the distressed pathway to reach the area of inspection of the ESR. The condition of the structure was poor due to age factor. However, the major RCC structures were inspected with the method of visual inspection as well as Non-Destructive testing. The paper illustrates the unique methodology of Restoration on Elevated Storage Reservoirs such as Micro concreting and Fibre Wrapping work for RCC members, Internal Waterproofing of ESR and Special anti Carbonation Treatment to the entire external surface and other remedial measures for its Major Repair and Rehabilitation.

Key Words

ESR, Recommendations, Micro concreting, Waterproofing

Cite This Article

"REPAIR, REHABILITATION AND RETROFITTING OF ELEVATED STORAGE RESERVOIR (ESR) SITUATEDAT THANE FOR THANE MUNICIPAL CORPORATION- A CASE STUDY", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.4, Issue 12, page no.1040-1044, December-2017, Available :http://www.jetir.org/papers/JETIR1712144.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"REPAIR, REHABILITATION AND RETROFITTING OF ELEVATED STORAGE RESERVOIR (ESR) SITUATEDAT THANE FOR THANE MUNICIPAL CORPORATION- A CASE STUDY", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.4, Issue 12, page no. pp1040-1044, December-2017, Available at : http://www.jetir.org/papers/JETIR1712144.pdf

Publication Details

Published Paper ID: JETIR1712144
Registration ID: 171157
Published In: Volume 4 | Issue 12 | Year December-2017
DOI (Digital Object Identifier):
Page No: 1040-1044
Country: Mumbai, Maharastra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003104

Print This Page

Current Call For Paper

Jetir RMS