Title

Strengthening of Reinforced Concrete Columns Wrapped with GFRP.

Authors

Abstract

The use of fiber reinforced polymer (FRP) materials for structural repair and strengthening has continuously increased in recent years, due to several advantages associated with these composites when compared to conventional materials like steel.. One of the most practical applications of these materials is concerned with the strengthening and retrofitting concrete compression members by means of external confinement with the Glass Fiber Reinforced Sheets. The role of Fiber Reinforced Polymer for strengthening of existing concrete structures is growing at an extremely rapid pace owing mainly to the ease and speed of construction, and the possibility of application without disturbing the existing functionality of the structure. In the present study experimental investigations were carried out on the behavior of standard concrete columns externally wrapped with fiber reinforced polymer composites. These concrete cylinders are subjected to pure compression with various confinement ratios. Experimental results indicate that strength of the confined concrete cylinders has significant impact on the number of layers of composites. The paper addresses the study of the effect of number of layers on the compressive failure for a given slenderness ratio using numerical technique. The experimental data, in terms of failure strength are compared with numerical technique results and the quality of the approximation is analyzed.

Key Words

Concrete cylinders, Glass Fiber Reinforced Polymer (GFRP), Confinement

Cite This Article

"Strengthening of Reinforced Concrete Columns Wrapped with GFRP.", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 2, page no.115-118, February-2018, Available :http://www.jetir.org/papers/JETIR18MG022.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Strengthening of Reinforced Concrete Columns Wrapped with GFRP.", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 2, page no. pp115-118, February-2018, Available at : http://www.jetir.org/papers/JETIR18MG022.pdf

Publication Details

Published Paper ID: JETIR18MG022
Registration ID: 180332
Published In: Volume 5 | Issue 2 | Year February-2018
DOI (Digital Object Identifier):
Page No: 115-118
Country: HYDERABAD, Telangana, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003125

Print This Page

Current Call For Paper

Jetir RMS