UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 1
January-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1901C48


Registration ID:
226305

Page Number

1063-1069

Share This Article


Jetir RMS

Title

Effect of Spacing in a Parallel Plate Stack on the Performance of Thermoacoustic Refrigerator made up of PVC for an Operating Pressure of 8 bar using Air as a Working Medium

Abstract

In this experimental study, Poly-Vinyl-Chloride (PVC) has been used to fabricate all the structural parts of the Thermoacoustic Refrigerator (TAR) including the resonator system to minimize the conduction heat losses between the refrigerator and the surroundings. In this work, three parallel plate stacks are used to study the performance of TAR by considering different porosity ratios by varying the gap between the parallel plates (0.28 mm, 0.33 mm, and 0.38 mm). The parallel plate stacks are constructed by using aluminum and mylar sheets and Air is used as the working. Present research deals with the study of performance of thermoacoustic refrigerator of 10W cooling power for different operating conditions with a constant mean operating pressure of 8 bar. The experiments are conducted for three drive ratios of 0.6%, 1% and 1.6% with an operating frequencies of 200 – 600 Hz and cooling load of 2W – 10W. The effect of different parameters on the performance of thermoacoustic refrigerator such as operating frequency, cooling load and drive ratios are studied. Experimental results shows that the lowest temperature measured at cold heat exchanger is 1.91 oC while the hot heat exchanger temperature is maintained between 31 oC – 32 oC. The highest value of temperature difference (∆T) measured is 29.44 oC which shows the improvement of about 32% increase in the temperature difference than the previous findings where aluminum resonator is used. The highest Coefficient of Performance (COP) and the Relative Coefficient of Performance (COPR) are found to be 1.490 and 0.137 respectively.

Key Words

Thermoacoustic Refrigerator; Drive Ratio; Parallel Plate Stack; COP; COPR; Temperature Difference

Cite This Article

"Effect of Spacing in a Parallel Plate Stack on the Performance of Thermoacoustic Refrigerator made up of PVC for an Operating Pressure of 8 bar using Air as a Working Medium", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 1, page no.1063-1069, January-2019, Available :http://www.jetir.org/papers/JETIR1901C48.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Effect of Spacing in a Parallel Plate Stack on the Performance of Thermoacoustic Refrigerator made up of PVC for an Operating Pressure of 8 bar using Air as a Working Medium", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 1, page no. pp1063-1069, January-2019, Available at : http://www.jetir.org/papers/JETIR1901C48.pdf

Publication Details

Published Paper ID: JETIR1901C48
Registration ID: 226305
Published In: Volume 6 | Issue 1 | Year January-2019
DOI (Digital Object Identifier):
Page No: 1063-1069
Country: Bengaluru, KARNATAKA, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002858

Print This Page

Current Call For Paper

Jetir RMS