UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 3 | March 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 7 Issue 3
March-2020
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2003270


Registration ID:
229939

Page Number

1890-1896

Share This Article


Jetir RMS

Title

Comparative Study of CR Artifact Due To Technical and Movements Errors

Abstract

Objective To determine utility evaluation of patient preparation techniques and effective handling of the equipment Available and Evaluation of routine practices followed by the technologist and to understand the basic compromises noticeable while using CR. Methods 40 X-Rays were studied at the department of radiology CS Subharti Hospital Meerut from September 1, 2017 to June 25, 2018. various factors which causes artifacts seen on films were noted. Results Out of 40 cases, It was observed that maximum no. of artifacts are caused by image processing 20(50%) while minimum artifacts are caused by patient movement 9(22.5%). Artifact caused by image acquisition i.e 11(27.5%). In comparative study 31(77.5%) was caused due to technical error which include Image Acquisition Artifact and Image Processing Artifact. Minimum error i.e 9(22.5%) was caused due to Patient Movement. Conclusion Artifacts on radiographic images are distracting and may compromise accurate diagnosis. Although most artifacts that occur in conventional radiography have become familiar, computed radiography. Understanding the potential sources of CR artifacts will aid in identifying and resolving problems quickly and help prevent future occurrences.

Key Words

Assessment various factors which causes artifacts.

Cite This Article

"Comparative Study of CR Artifact Due To Technical and Movements Errors", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 3, page no.1890-1896, March-2020, Available :http://www.jetir.org/papers/JETIR2003270.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Comparative Study of CR Artifact Due To Technical and Movements Errors", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 3, page no. pp1890-1896, March-2020, Available at : http://www.jetir.org/papers/JETIR2003270.pdf

Publication Details

Published Paper ID: JETIR2003270
Registration ID: 229939
Published In: Volume 7 | Issue 3 | Year March-2020
DOI (Digital Object Identifier):
Page No: 1890-1896
Country: Saharanpur, uttar pradesh, India .
Area: Medical Science
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003016

Print This Page

Current Call For Paper

Jetir RMS