JETIREXPLORE- Search Thousands of research papers



Published in:

Volume 7 Issue 7
July-2020
eISSN: 2349-5162

Unique Identifier

JETIR2007077

Page Number

632-636

Share This Article


Title

Redesign the Sheilding Cylinder to Minimize the Grid Outage due to Shunt Reactor Failure

ISSN

2349-5162

Cite This Article

"Redesign the Sheilding Cylinder to Minimize the Grid Outage due to Shunt Reactor Failure ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 7, page no.632-636, July-2020, Available :http://www.jetir.org/papers/JETIR2007077.pdf

Abstract

Grid outage is the state of complete absence of electricity at the consumer’s end. There are many causes of power failures in a Grid. One of the causes is the shunt reactor failure at transmission substations. Shunt reactor is an intensive key component of transmission substation for maintaining continuous flow of electricity. It is installed for improving the efficiency of transmission line through reactive power compensation and to offset the capacitive effect of the transmission line and to regulate the voltage and reactive power. In case of failure of shunt reactor in long transmission line system, voltage of system shoots up which may lead to forced outages of the system. In this paper ,present here to work on the development of new robust, operator friendly & more reliable earthing lead of shield cylinder that is very important the part of shunt reactor

Key Words

Shielding Cylinder, Shunt Reactor Failure, Grid Outage, Redsign etc

Cite This Article

"Redesign the Sheilding Cylinder to Minimize the Grid Outage due to Shunt Reactor Failure ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 7, page no. pp632-636, July-2020, Available at : http://www.jetir.org/papers/JETIR2007077.pdf

Publication Details

Published Paper ID: JETIR2007077
Registration ID: 235005
Published In: Volume 7 | Issue 7 | Year July-2020
DOI (Digital Object Identifier):
Page No: 632-636
ISSN Number: 2349-5162

Download Paper

Preview Article

Download Paper




Cite This Article

"Redesign the Sheilding Cylinder to Minimize the Grid Outage due to Shunt Reactor Failure ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 7, page no. pp632-636, July-2020, Available at : http://www.jetir.org/papers/JETIR2007077.pdf