MINIMIZATION OF PROCESS HEAT DISSIPATION TO COOLING TOWER

Abstract

Cooling towers are hidden profits for energy conservation and cost effective when properly engineered and maintained. The savings accrued in energy conservation and additional product manufactured can be an important factor of an industries profits. In industry there are many waste heat sources are available. Existing technology for this is used cooling tower and modern technology are using heat pump, VAM,ORC(organic rankine cycle). In this research paper waste heat from compression is recovered by adding split type heat exchanger from which it is passed to VAM (vapor absorption machine). VAM is used for obtaining chilled water. This chilled water can be used to decrease the temperature of the gas at suction of compressor. In result we get less shaft power requirement for compression. Thus from waste heat we can make profit for industry

Key Words

Cooling tower, VAM,ORC

Cite This Article

"MINIMIZATION OF PROCESS HEAT DISSIPATION TO COOLING TOWER", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 9, page no.569-573, September-2020, Available :http://www.jetir.org/papers/JETIR2009077.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"MINIMIZATION OF PROCESS HEAT DISSIPATION TO COOLING TOWER", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 9, page no. pp569-573, September-2020, Available at : http://www.jetir.org/papers/JETIR2009077.pdf

Publication Details

Published Paper ID: JETIR2009077
Registration ID: 300651
Published In: Volume 7 | Issue 9 | Year September-2020
DOI (Digital Object Identifier):
Page No: 569-573
Country: navi mumbai, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003068

Print This Page

Current Call For Paper

Jetir RMS