Simulation of Three Phase Transformer-less Shunt Active Power Filter for Harmonic Compensation in Grid Connected Applications

Abstract

Shunt active power filter is the preeminent solution against nonlinear loads, current harmonics and power quality problems. APF topologies for harmonic compensation use numerous high-power rating components and are therefore disadvantageous. Hybrid topologies combining low-power rating APF with passive filters are used to reduce the power rating of voltage source inverter. Hybrid APF topologies for high-power rating systems use a transformer with large numbers of passive components. In this project a novel four-switch two-leg VSI topology for a three-phase SAPF is proposed for reducing the system cost and size. The proposed topology comprises a two-arm bridge structure, four switches, coupling inductors, and sets of LC PFs. The third leg of the three-phase VSI is removed by eliminating the set of power switching devices, thereby directly connecting the phase with the negative terminals of the dc-link capacitor. The proposed topology enhances the harmonic compensation capability and provides complete reactive power compensation compared with conventional APF topologies. The simulation and analysis of 3-phase transformer less SAPF is carried out using Matlab-Simulink.

Key Words

SAPF, VSI, APF, LC-Filters, Harmonics, etc.

Cite This Article

"Simulation of Three Phase Transformer-less Shunt Active Power Filter for Harmonic Compensation in Grid Connected Applications", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 11, page no.325-341, November-2020, Available :http://www.jetir.org/papers/JETIR2011048.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Simulation of Three Phase Transformer-less Shunt Active Power Filter for Harmonic Compensation in Grid Connected Applications", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 11, page no. pp325-341, November-2020, Available at : http://www.jetir.org/papers/JETIR2011048.pdf

Publication Details

Published Paper ID: JETIR2011048
Registration ID: 303188
Published In: Volume 7 | Issue 11 | Year November-2020
DOI (Digital Object Identifier):
Page No: 325-341
Country: Mehsana, Gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002995

Print This Page

Current Call For Paper

Jetir RMS