UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 9
September-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIRB006062


Registration ID:
186299

Page Number

333-339

Share This Article


Jetir RMS

Title

Effect of Thermally-Enhanced Backfilling Materials on the Performance of Earth-Air- Tunnel-Heat-Exchanger System: A Review

Abstract

Building cooling and heating consume around one-third of total primary energy consumption.Renewable and passive systems can reduce the building cooling and heating energy demand. Earth air tunnel heat exchanger (EATHE) is one of the promising passive techniques which can serve the purpose of space heating and cooling using constant temperature of underground soil. It is a promissing passive technique for space heating and cooling butit required long pipes and largeland area for installation of pipes. Various studies have been conducted in last few decades to investigate the various parameters that may reduce the length of pipe and land area requirement. In this article, the effect of thermal properties of soilon the performance of earth air heat exchanger systems have been reviewed.This review article shows that length of pipe and land area requirement for EATHE pipe installation can be substantially reduced by using thermally enhanced backfilling material at the vicinity of the EATHE pipe.

Key Words

EATHE system, thermal properties of soil, pipe length, land area requirement, thermally-enhanced backfilling materials.

Cite This Article

"Effect of Thermally-Enhanced Backfilling Materials on the Performance of Earth-Air- Tunnel-Heat-Exchanger System: A Review", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 9, page no.333-339, September-2018, Available :http://www.jetir.org/papers/JETIRB006062.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Effect of Thermally-Enhanced Backfilling Materials on the Performance of Earth-Air- Tunnel-Heat-Exchanger System: A Review", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 9, page no. pp333-339, September-2018, Available at : http://www.jetir.org/papers/JETIRB006062.pdf

Publication Details

Published Paper ID: JETIRB006062
Registration ID: 186299
Published In: Volume 5 | Issue 9 | Year September-2018
DOI (Digital Object Identifier):
Page No: 333-339
Country: Udaipur, Rajasthan, India .
Area: Science & Technology
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002983

Print This Page

Current Call For Paper

Jetir RMS