Analysis of rooftop solar system’s performance under real conditions

Authors

Abstract

Performance of rooftop solar power system under real climatic conditions was studied for a particular day of consideration. The present study covered all three types of Si modules like amorphous (a-Si), mono crystalline (Mono-Si) and poly crystalline (Poly-Si) was compared for their behaviour against change in temperature and irradiance. Different crucial solar module characteristics like efficiency, short circuit current, open circuit voltage and fill factor were scrutinised to find out the temperature coefficient of open circuit voltage of all three technologies. The derived values of temperature coefficients for a-Si, Mono-Si and Poly-Si modules are -0.068, -0.063 and -0.066 V/oC, respectively. Moreover, nature of variation in fill factor (FF) with temperature was studied and maximum change in FF is about 0.18%, 0.25% and 0.5% for a-Si, Mono-Si and Poly-Si, respectively. This study will help end users to opt for an appropriate selection of Si modules based on real climatic conditions on a site of installation.

Key Words

Cite This Article

"Analysis of rooftop solar system’s performance under real conditions", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 2, page no.197-201, February-2019, Available :http://www.jetir.org/papers/JETIREL06038.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Analysis of rooftop solar system’s performance under real conditions", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 2, page no. pp197-201, February-2019, Available at : http://www.jetir.org/papers/JETIREL06038.pdf

Publication Details

Published Paper ID: JETIREL06038
Registration ID: 305946
Published In: Volume 6 | Issue 2 | Year February-2019
DOI (Digital Object Identifier):
Page No: 197-201
Country: Phagwara, Punjab, India .
Area: Science
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002894

Print This Page

Current Call For Paper

Jetir RMS