UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 9
September-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1809779


Registration ID:
189101

Page Number

882-885

Share This Article


Jetir RMS

Title

PERFORMANCE OF SERPENTINE CONDENSER SUB COOLING EFFECT ON THE VAPOUR COMPRESSION REFRIGERATION SYSTEM USING R600A

Abstract

In this paper, Performance of serpentine condenser sub cooling effect on the vapour compression refrigeration system using R600a is presented, which operates using directly alternatives refrigerants, have poorer energy parameters compared with R134a.The cooling capacity amounts are also desired to be kept constant while changing the refrigerant of the systems originally designed and constructed to work with R134a. In order to achieve this aim, performance of R600a refrigerant was investigated by a serpentine condenser to following Liquid-suction heat exchanger for a refrigerator operating with R134a .Therefore, smaller discharge pressure of the compressor ,decreased electricity consumption ,increased in sub cooling temperature and enhanced cooling capacity amounts were intended in this study. The results obtained through this study have shown that, in the sub cooling temperature interval from 0°C to 14°C, the condenser additive surface is lower for R600a refrigerant compared to R134a COP increased up to 16.5% under a sub cooling temperature of 8°C to 14°C. The results in increased of COP in vapour compression refrigeration system as a result of using R600a as an alternative to R134a with the presence of a serpentine condenser and Liquid-suction heat exchanger in the system

Key Words

Domestic refrigerator, Serpentine condenser, sub cooling, Coefficient of performance (COP). LSHE

Cite This Article

"PERFORMANCE OF SERPENTINE CONDENSER SUB COOLING EFFECT ON THE VAPOUR COMPRESSION REFRIGERATION SYSTEM USING R600A", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 9, page no.882-885, September-2018, Available :http://www.jetir.org/papers/JETIR1809779.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"PERFORMANCE OF SERPENTINE CONDENSER SUB COOLING EFFECT ON THE VAPOUR COMPRESSION REFRIGERATION SYSTEM USING R600A", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 9, page no. pp882-885, September-2018, Available at : http://www.jetir.org/papers/JETIR1809779.pdf

Publication Details

Published Paper ID: JETIR1809779
Registration ID: 189101
Published In: Volume 5 | Issue 9 | Year September-2018
DOI (Digital Object Identifier):
Page No: 882-885
Country: naidupeta, ANDHRA PRADESH, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003015

Print This Page

Current Call For Paper

Jetir RMS