UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 7 Issue 7
July-2020
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2007014


Registration ID:
234816

Page Number

118-133

Share This Article


Jetir RMS

Title

SEISMIC RESPONSE OF MULTI STOREY BUILDING WITH DUAL FUSED H FRAME SYSTEM

Abstract

A dual fused H-frame (DFHF) is an efficient structural system that combines damped H-frame (DHF) modules welded wide flanges fuses (WWFFs) to create a structural solution that is efficient in construction and more seismically resilient. Each DHF module consists of two columns pin connected to a beam with two buckling restrained knee braces (BRKBs).Each DHF module can be prefabricated at the factory , shipped to the site , and connected vertically using simple bolt connections .The connections between the DHF module have relatively small moment demand , which makes the design ,fabrication , and construction of the DHF modules very efficient . Once the DHF modules are assembeled vertically , the bays of the DHF can be connected using WWFFs. WWFFs are simple shear connector that can be stably dissipate earthquake energy.

Key Words

Seismicanalysis ,Response spectrum method and Time history method

Cite This Article

"SEISMIC RESPONSE OF MULTI STOREY BUILDING WITH DUAL FUSED H FRAME SYSTEM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 7, page no.118-133, July-2020, Available :http://www.jetir.org/papers/JETIR2007014.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"SEISMIC RESPONSE OF MULTI STOREY BUILDING WITH DUAL FUSED H FRAME SYSTEM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 7, page no. pp118-133, July-2020, Available at : http://www.jetir.org/papers/JETIR2007014.pdf

Publication Details

Published Paper ID: JETIR2007014
Registration ID: 234816
Published In: Volume 7 | Issue 7 | Year July-2020
DOI (Digital Object Identifier):
Page No: 118-133
Country: MANDYA, KARNATAKA, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002957

Print This Page

Current Call For Paper

Jetir RMS