A Review Paper on Power Quality Improvement by Harmonics Reduction Using Shunt Active Power Filter With p-q & d-q Current Control Strategy

Abstract

With the widespread use of power electronics devices such as rectifier, inverter etc. in power system causes serious problem relating to power quality. One of such problem is generation of current and voltage harmonics causing distortion of load waveform, voltage fluctuation, voltage dip, heating of equipment etc. Also presence of non-linear loads such as UPS, SMPS, speed drives etc. causes the generation of current harmonics in power system. They draw reactive power components of current from the AC mains, hence causing disturbance in supply current waveform. Thus to avoid the consequences of harmonics we have to compensate the harmonic component in power utility system. Among various method used, one of the effective method to reduce harmonic in power system is the use of Shunt Active Power Filter (SAPF). This Paper gives detail performance analysis of SAPF under two current control strategy namely, instantaneous active and reactive power theory (p-q) and synchronous frame reference theory (d-q) and their comparative analysis to justify one of the method better over other. In both method a reference current is generated for the filter which compensate either reactive power or harmonic current component in power system. In this paper, a current controller known harmonic current controller is described which is used provide corrective gating sequence of the IGBT inverter and thus helps to remove harmonics component.

Key Words

Shunt Active Power Filter (SAPF), Harmonics, Active Filter, passive Filter.

Cite This Article

"A Review Paper on Power Quality Improvement by Harmonics Reduction Using Shunt Active Power Filter With p-q & d-q Current Control Strategy", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.8, Issue 5, page no.b165-b168, May-2021, Available :http://www.jetir.org/papers/JETIR2105148.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"A Review Paper on Power Quality Improvement by Harmonics Reduction Using Shunt Active Power Filter With p-q & d-q Current Control Strategy", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.8, Issue 5, page no. ppb165-b168, May-2021, Available at : http://www.jetir.org/papers/JETIR2105148.pdf

Publication Details

Published Paper ID: JETIR2105148
Registration ID: 308986
Published In: Volume 8 | Issue 5 | Year May-2021
DOI (Digital Object Identifier):
Page No: b165-b168
Country: KODINAR, Gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000479

Print This Page

Current Call For Paper

Jetir RMS