Study of lead Ion Selective Membrane Electrode Formed by Cation Exchanger 2-amino-4 methyl -N-hydroxy-benzene-carboxamide (AMHBCA) for the Selective and Determination of Pb2+ Ions

Authors

Abstract

A lead ion selective composite cation exchanger 2,-amino-4 methyl -N-hydroxy-benzene-carboxamide (AMHBCA) was used as electro active component for the construction of a ion selective membrane electrode. The membrane electrode are formed by using plasticizer dibutyl(butyl) phosphonate (DBBP), diisodecyl Phthalate (DIDP), diisononyl Phthalate (DINP) and PVC in different composition. The membrane electrode formed by using diisodecyl Phthalate (DIDP) plasticizer showed a Nernstian response 28.6 mv per decade for Pb2+ ions over a wide concentration range. The electrode works satisfactory in the concentration range 6.0×10-5 to 1.0×10-1 M with near Nernstian slope of 29.6 mv per decade of concentration between pH from 2.6 to 5.8.The electrode also showed better selectivity for Pb2+ ion over many interfering ions. Results of the investigation reveal that the membrane electrode prepared by using 4 mg of organic ion exchange (AMHBCA), 80 mg DIDP and 150 mg PVC is the best. The performance of the electrodes is comparable with existing electrode in term of working concentration range, slope, pH, response time and selectivity over a number of cations.

Key Words

Plasticizer, Ion selective membrane electrode, Pb2+, pH, Nernstian response, selectivity, solvent effect.

Cite This Article

"Study of lead Ion Selective Membrane Electrode Formed by Cation Exchanger 2-amino-4 methyl -N-hydroxy-benzene-carboxamide (AMHBCA) for the Selective and Determination of Pb2+ Ions", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 1, page no.a118-a125, January-2022, Available :http://www.jetir.org/papers/JETIR2201015.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Study of lead Ion Selective Membrane Electrode Formed by Cation Exchanger 2-amino-4 methyl -N-hydroxy-benzene-carboxamide (AMHBCA) for the Selective and Determination of Pb2+ Ions", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 1, page no. ppa118-a125, January-2022, Available at : http://www.jetir.org/papers/JETIR2201015.pdf

Publication Details

Published Paper ID: JETIR2201015
Registration ID: 318574
Published In: Volume 9 | Issue 1 | Year January-2022
DOI (Digital Object Identifier):
Page No: a118-a125
Country: Modinagar, U.P., India .
Area: Chemistry
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000408

Print This Page

Current Call For Paper

Jetir RMS