UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 11 | November 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 10 Issue 1
January-2023
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2301176


Registration ID:
507095

Page Number

b548-b558

Share This Article


Jetir RMS

Title

PERFORMANCE ANALYSIS OF COUNTER TO CROSS FLOW HEAT EXCHANGER WITH DIFFERENT FAN ANGLES

Authors

Abstract

A heat exchanger is device which heat exchangers among two or more fluids. Heat exchanger are using for the heating and cooling systems in domestic and industrial operations. When heat exchanger devices are used in any operation than some heat losses in atmosphere. We studied different research paper and analysed the performance parameter of heat exchangers. After studied of different research paper, I found new idea to get better the thermal performances of counter to cross flow by using air cooled heat exchanger [ACHE] process. Constrained geometry structures are counter to cross flow using air cooled heat exchangers process. In air cooled heat exchanger [ACHE] process is using internal grooved aluminium concentric tube and aluminium fins. Hot water will be flow in spiral grooved aluminium tube and rectangular fins will be fitted on tube. A fan will be fitted perpendicular to the tube which expand cold air through the fan on tube. In this study, time-domain simulations are performed for the National Advisory Committee for Aeronautics Air foil 6512 propeller. NACA 0015 was used for blade inner fan with a variety of inner fan blade angles 150, 300, 450 and 600 and varied wind speed to turbine ventilator 1.5, 3, 4.5 and 6 m/s. The fans will blow the air on tube due to hot fluid will be decreases the temperature outlet of tube. We will be temperature difference found input and output of the hot fluid.

Key Words

Air Cooled Heat Exchanger, Internal grooved tubes, Rectangular Aluminium fins, Rectangluar Copper fins.

Cite This Article

"PERFORMANCE ANALYSIS OF COUNTER TO CROSS FLOW HEAT EXCHANGER WITH DIFFERENT FAN ANGLES", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.10, Issue 1, page no.b548-b558, January-2023, Available :http://www.jetir.org/papers/JETIR2301176.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"PERFORMANCE ANALYSIS OF COUNTER TO CROSS FLOW HEAT EXCHANGER WITH DIFFERENT FAN ANGLES", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.10, Issue 1, page no. ppb548-b558, January-2023, Available at : http://www.jetir.org/papers/JETIR2301176.pdf

Publication Details

Published Paper ID: JETIR2301176
Registration ID: 507095
Published In: Volume 10 | Issue 1 | Year January-2023
DOI (Digital Object Identifier):
Page No: b548-b558
Country: CHHATARPUR, MADHYA PRADESH, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000158

Print This Page

Current Call For Paper

Jetir RMS