Three Phase Fault Detection with Auto Reset for Temporary Fault and Trip for Permanent Fault

Download Paper

Abstract

This paper to develop an automatic tripping mechanism for the three-phase supply system. The project output resets automatically after a brief interruption in the event temporary fault while it remains in tripped condition in case of permanent fault. The electrical substation which supply the power to the consumers, have failures due to some faults which can be temporary or permanent. These faults lead to substantial damage to the power system equipment. In India, it is common, the faults might be LG (Line to Ground), LL (Line to Line), 3L (Three lines) in the supply systems and these faults in three phase supply system can affect the power system. To overcome this problem a system is built, which can sense these faults and automatically disconnects the supply to avoid large scale damage to the control gears in the grid sub-stations. This system is built using three single phase transformers which are wired in star input and star output, and 3 transformers are connected in delta connections, having input 220 volt and output at 12 volts. This concept low voltage testing of fault conditions is followed as it is not advisable to create on mains line. 555 timers are used for handling short duration and long duration fault conditions. A set of switches are used to create the LL, LG and 3L fault in low voltage side, for activating the tripping mechanism. Short duration fault returns the supply to the load immediately called as temporary trip while long duration shall result in permanent trip. The concept in the future can be extended to developing a mechanism to send message to the authorities via SMS by interfacing a GSM modem..

Key Words

Cite This Article

"Three Phase Fault Detection with Auto Reset for Temporary Fault and Trip for Permanent Fault", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.4, Issue 9, page no. pp109-111, September-2017, Available at : www.jetir.org & http://www.jetir.org/JETIR1709022

Publication Details

Published Paper ID: JETIR1709022
Registration ID: 170597
Published In: Volume 4 | Issue 9 | Year September-2017
DOI (Digital Object Identifier):
Page No: 109-111
ISSN Number: 2349-5162

Download Paper


UGC and ISSN Approved Journal | Call For Paper
(Volume 4 | Issue 11 | November 2017 |Impact factor 5.87)

Call For Paper | Volume 4 | Issue 11 | Impact factor 5.87


Important Dates Related to Publication Procedure:
  • » Paper Submission Till: 29 November 2017.
  • » UGC and ISSN Approved Journal
  • » Review (Acceptance/Rejection) Notification: Within 02-04 Days.
  • » Paper Publish:Within 02-07 Days after submitting the all documents.
  • » Frequency: Monthly (12 issue Annually)
  • » Journal Type : Open Access
  • » Publication Charges : 1300 INR
  • »Indexing In Google Scholar, ResearcherID Thomson Reuters, Mendeley : reference manager, Academia.edu, arXiv.org, Research Gate, CiteSeerX, DocStoc, ISSUU, Scribd, and many more | High Impact Factor: 5.87 Digital object identifier (DOI) and Hard Copy of certificate Provided.
Publication and Indexing Patner:




Preview This Article


Downlaod

Download PDF

Downloads

000704

Print This Page

Impact Factor

Impact factor: 5.87

Jetir RMS