JETIREXPLORE- Search Thousands of research papers



Published in:

Volume 5 Issue 4
April-2018
eISSN: 2349-5162

Unique Identifier

JETIR1804262

Page Number

205-214

Share This Article


Title

An Investigation of Response Reduction Factor of RCC framed staging elevated water tank using Nonlinear Pushover Analysis

ISSN

2349-5162

Cite This Article

"An Investigation of Response Reduction Factor of RCC framed staging elevated water tank using Nonlinear Pushover Analysis ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 4, page no.205-214, April-2018, Available :http://www.jetir.org/papers/JETIR1804262.pdf

Abstract

The basic principal of earthquake resistance design of structures is that the structure should not collapse but damage to the structural elements is permitted. Water tank is very valuable structure. Staging type of tanks is generally collapse during earthquake, so it is required to calculate earthquake load properly. Past evidence had shown that the elevated tanks are susceptible. due to earthquake. The tanks are designed based on linear elastic methods which are considered only elastic range. Factor shows the reserved strength of water tank in IS 1893-2016(Part-2) value of R factor for RC elevated shaft supported tank is 2.5 and for column supported 4. One constant R-value for elevated water tank cannot reflect the expected inelastic behavior of all elevated water tanks located in different seismic zone, different soil condition, and having different height. So it is requisite to find out absolute value of R factor for various type of RC elevated tank individually. The present study efforts are made to evaluate the response reduction factor of RC framed staging elevated water tank having varying staging height, capacities, soil condition and zones. The main objective of this study is to verify the R factor of most common designed Elevated Intze tank through comparing the assumed R factor during design to actual R factor obtained from non-linear analysis.

Key Words

SAP2000, R-Factor, Time Period, Ductility Factor, Redundancy Factor

Cite This Article

"An Investigation of Response Reduction Factor of RCC framed staging elevated water tank using Nonlinear Pushover Analysis ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 4, page no. pp205-214, April-2018, Available at : http://www.jetir.org/papers/JETIR1804262.pdf

Publication Details

Published Paper ID: JETIR1804262
Registration ID: 181346
Published In: Volume 5 | Issue 4 | Year April-2018
DOI (Digital Object Identifier):
Page No: 205-214
ISSN Number: 2349-5162

Download Paper

Preview Article

Download Paper




Cite This Article

"An Investigation of Response Reduction Factor of RCC framed staging elevated water tank using Nonlinear Pushover Analysis ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 4, page no. pp205-214, April-2018, Available at : http://www.jetir.org/papers/JETIR1804262.pdf




Preview This Article


Downlaod

Click here for Article Preview