STUDY OF PERFORMANCE PARAMETERS OF INCLINED HEAT PIPE FITTED WINDOW A/C SYSTEM

Abstract

This paper mainly covers experimental investigation of the effect of fitting a heat pipe in an window air conditioner. A conventional air conditioner consumes 30-35% of energy in reheating the over-cooled air. A heat pipe can be used to reheat the over-cooled air gaining heat from the hot air leaving the condenser. The current investigation studies the effect of fitting an inclined heat pipe in a 1.5 Ton window air conditioner. The heat pipe is fabricated using copper pipe as the container, R-11 as the working fluid and cotton as wick material. It has been observed that use of heat pipe in air conditioner has substantial effect if used at proper location.

Key Words

heat pipe, Window AC, heat addition & removal, performance analysis.

Cite This Article

"STUDY OF PERFORMANCE PARAMETERS OF INCLINED HEAT PIPE FITTED WINDOW A/C SYSTEM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 5, page no.413-419, May-2019, Available :http://www.jetir.org/papers/JETIR1905260.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"STUDY OF PERFORMANCE PARAMETERS OF INCLINED HEAT PIPE FITTED WINDOW A/C SYSTEM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 5, page no. pp413-419, May-2019, Available at : http://www.jetir.org/papers/JETIR1905260.pdf

Publication Details

Published Paper ID: JETIR1905260
Registration ID: 209064
Published In: Volume 6 | Issue 5 | Year May-2019
DOI (Digital Object Identifier):
Page No: 413-419
Country: Pune, Maharashtra state, India .
Area: Science & Technology
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002909

Print This Page

Current Call For Paper

Jetir RMS