UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 5
May-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1905363


Registration ID:
209645

Page Number

452-461

Share This Article


Jetir RMS

Title

Defining the parameter for optimisation the performance, and Vacuum level of water ring pump of 904 series.

Abstract

With increasing demand of vacuum pump also require high performance of pump demanded by market. Vacuum pump to give their function properly but many vacuum pumps not give work properly as per requirement just because of poor design of vacuum pump. So design of pump being changed to improve function, but it is costly and time consuming using experimental work. So CFD analysis use for this purpose. The main objective of this project is to improve vacuum level of water ring vacuum pump. In Fine tech engineering during testing process of water ring vacuum pump see that in WRVP the vacuum level is very low as per requirement and therefore efficiency is low. To improve the efficiency of SV-20 water ring vacuum pump, Computational Fluid Dynamics analysis is one of the advanced tools used in the pump industry. A detailed CFD analysis is used to predict the flow pattern inside the impeller which is an active pump component. From the result of CFD analysis, vacuum level of impeller is justified and validated with experimental result here with very low deviation in result of 2.24%. Now modified impellers are modelled using CAD modelling software. Here we changed thickness of blade, inlet and outlet angle of impeller based on empirical relation and literature. Here 11 modified impellers remodelled. These models are analysed individually using CFD analysis to fing the performance of the modified impeller WRVP. By using CFD analysis impellers with the improved value of vacuum level 485.88mm of hg vacuum get and by means improved efficiency achieve. Key word :Vaccum pump,CFD,Impeller,Blade Thickness.

Key Words

Vaccum pump,CFD,Impeller,Blade Thickness.

Cite This Article

"Defining the parameter for optimisation the performance, and Vacuum level of water ring pump of 904 series.", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 5, page no.452-461, May-2019, Available :http://www.jetir.org/papers/JETIR1905363.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Defining the parameter for optimisation the performance, and Vacuum level of water ring pump of 904 series.", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 5, page no. pp452-461, May-2019, Available at : http://www.jetir.org/papers/JETIR1905363.pdf

Publication Details

Published Paper ID: JETIR1905363
Registration ID: 209645
Published In: Volume 6 | Issue 5 | Year May-2019
DOI (Digital Object Identifier):
Page No: 452-461
Country: Vadodara, Gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002877

Print This Page

Current Call For Paper

Jetir RMS