DESIGN AND ANALYSIS OF MW SCALE SUB-STATION FED BY WINDFARM WITH SUPERCONDUCTING FAULT CURRENT LIMITER

Abstract

This paper describes the Short circuit analysis for the proposed 220/33kV substation for finding the Maximum & minimum fault level at substation & fault level feeding from the grid network in E Tap. For this a grid network was assumed. With the Maximum & Minimum fault levels arrived from analysis protective relay coordination carried out for the entire proposed 220/33kV substation in E tap. Here the substation is fed with Renewable source, Wind farm. With assumption of growth in IPPs (Independent power purchasers), the fault level feeding to our substation from grid will be increased. So, to mitigate the fault level at our proposed 220/33kV substation, super conducting fault current limiter (SFCL) is implemented. The results & comparisons of fault levels are carried out in MATLAB Simulink with & without SFCL device. It confirms that the presence of SFCL worked out outstandingly in the fault current reduction

Key Words

Wind resource assessment, Load Flow, Short circuit, protection coordination, TCC curves, ETAP, SFCL

Cite This Article

"DESIGN AND ANALYSIS OF MW SCALE SUB-STATION FED BY WINDFARM WITH SUPERCONDUCTING FAULT CURRENT LIMITER", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 3, page no.344-352, March-2018, Available :http://www.jetir.org/papers/JETIR1803070.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"DESIGN AND ANALYSIS OF MW SCALE SUB-STATION FED BY WINDFARM WITH SUPERCONDUCTING FAULT CURRENT LIMITER", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 3, page no. pp344-352, March-2018, Available at : http://www.jetir.org/papers/JETIR1803070.pdf

Publication Details

Published Paper ID: JETIR1803070
Registration ID: 180635
Published In: Volume 5 | Issue 3 | Year March-2018
DOI (Digital Object Identifier): http://doi.one/10.1717/JETIR.17340
Page No: 344-352
Country: Hyderabad, Telengana, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003096

Print This Page

Current Call For Paper

Jetir RMS