UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 5
May-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1805396


Registration ID:
182278

Page Number

1283-1292

Share This Article


Jetir RMS

Title

Reliability Enhancement by Using SFCL in A Distribution System with Distributed Generation Units

Abstract

The power distribution system with distributed generation (DG) units, its fault current and overvoltage under disturbance conditions ought to be taken into account. In consideration that applying superconducting fault current limiter (SFCL) may be a feasible arrangement, in this paper, the impacts of a voltage compensation typr active SFCL on them are contemplated through theoretical derivation and simulation. The active SFCL is made out of an air-core superconducting transformer and a PWM converter. The magnetic field in the air-core can be controlled by adjusting the converters output current, and then the active SFCLs equivalent impedance can be regulated for current limitation and conceivable over voltage concealment. During the examination procedure, in perspective of the changes in the locations of the DG units associated with the framework, the DG units injection capacities and the fault positions, the active SFCLs current-limiting and over voltage suppressing characteristics are both simulated in MATLAB. The simulation comes about demonstrate that the active SFCL can play an undeniable part in restraining the fault current and overvoltage, and it can add to avoiding damage on the relevant distribution system with distributed generation and enhance the systems safety and reliability.

Key Words

Distributed generation (DG), Reliability, distribution system, overvoltage, short-circuit current, voltage compensation type active superconducting fault current limiter (SFCL).

Cite This Article

"Reliability Enhancement by Using SFCL in A Distribution System with Distributed Generation Units", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 5, page no.1283-1292, May-2018, Available :http://www.jetir.org/papers/JETIR1805396.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Reliability Enhancement by Using SFCL in A Distribution System with Distributed Generation Units", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 5, page no. pp1283-1292, May-2018, Available at : http://www.jetir.org/papers/JETIR1805396.pdf

Publication Details

Published Paper ID: JETIR1805396
Registration ID: 182278
Published In: Volume 5 | Issue 5 | Year May-2018
DOI (Digital Object Identifier):
Page No: 1283-1292
Country: warangal, telangana, other .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002951

Print This Page

Current Call For Paper

Jetir RMS