UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 8
August-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1808422


Registration ID:
186776

Page Number

835-841

Share This Article


Jetir RMS

Title

THREE PHASE FIVE LEVEL INVERTER BASED DSTATCOM USING FLC CONTROL

Authors

Abstract

STATCOM can provide fast and efficient reactive power support to maintain power system voltage stability. In the literature, various STATCOM control methods have been discussed including many applications of PI controllers. However, these previous works obtain via a trial-and-error approach or extensive studies with a tradeoff of performance and applicability. Hence, control parameters for the optimal performance at a given operating point may not be effective at a different operating point. This project proposes a new control model based on fuzzy logic control, which can self-adjust the control gains during a disturbance such that the performance always matches a desired response, regardless of the change of operating condition. Since the adjustment is autonomous, this gives the plug-and-play capability for STATCOM operation. In the simulation test, the fuzzy logic control shows consistent excellence under various operating conditions, such as different initial control gains, different load levels, and change of transmission network, consecutive disturbances, and a severe disturbance. Here in STATCOM three phase five levels cascaded multilevel inverter is used as a voltage source converter. A threshold value of existing and proposed methods has been compared and the proposed threshold value is less than the existing system. Hence by using the fuzzy logic controller in proposed system reduced the threshold current and voltage values. So that improves the performance of operation in proposed system. The proposed method is simulated in 2013a MATLAB/SIMULINK.

Key Words

Cascaded multilevel converter, distribution, STATCOM (DSTATCOM), distribution transformer, winding taps, passivity-based control.

Cite This Article

"THREE PHASE FIVE LEVEL INVERTER BASED DSTATCOM USING FLC CONTROL", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 8, page no.835-841, August-2018, Available :http://www.jetir.org/papers/JETIR1808422.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"THREE PHASE FIVE LEVEL INVERTER BASED DSTATCOM USING FLC CONTROL", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 8, page no. pp835-841, August-2018, Available at : http://www.jetir.org/papers/JETIR1808422.pdf

Publication Details

Published Paper ID: JETIR1808422
Registration ID: 186776
Published In: Volume 5 | Issue 8 | Year August-2018
DOI (Digital Object Identifier):
Page No: 835-841
Country: tirupathi, chittoor distrct, andhra pradesh, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002833

Print This Page

Current Call For Paper

Jetir RMS