EVALUATION OF HEAT TRANSFER ON AIR RECUPERATOR

Abstract

Industrial waste heat refers to energy that is generated in industrial process without being put to practical use. It is estimated that somewhere between 20 to 50% industrial energy input is lost as waste heat in the form of hot exhaust gases, cooling water, heat lost from hot equipment surface and heated products. While some waste heat losses from industrial processes are inevitable. Facilities can reduce these losses by improving equipment efficiency or installing waste heat recovery technologies. In the steel making process, Rolling mills play a vital role in transforming the steel to finished Products. Rolling mills at Visakhapatnam Steel Plant consists of Light and medium merchant mill (LMMM), Wire Rod Mills (WRM) and Medium Merchant Structural Mills (MMSM). Air Recuperator is present in Medium Merchant Structural Mills (MMSM) section of the plant for the purpose of waste heat recovery. In this Medium Merchant Structural Mills (MMSM) section, air is pre-heated using the flue gas which enters the recuperator at high temperature from furnace. The pre-heated air is used in the furnace for heating the blooms. Volume flow rates and temperature of both flue gas and air are taken as input data. Heat transfer coefficient, friction factor and pressure drop on both air side and flue gas are estimated effectiveness of air recuperator is calculated. Graphs are drawn to show the performance of air recuperator the data arrived from the calculations with varying flow rates of air and flue gas are consolidated as table and put in appendix.

Key Words

Cite This Article

"EVALUATION OF HEAT TRANSFER ON AIR RECUPERATOR", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 9, page no.713-721, September-2018, Available :http://www.jetir.org/papers/JETIR1809137.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"EVALUATION OF HEAT TRANSFER ON AIR RECUPERATOR", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 9, page no. pp713-721, September-2018, Available at : http://www.jetir.org/papers/JETIR1809137.pdf

Publication Details

Published Paper ID: JETIR1809137
Registration ID: 187621
Published In: Volume 5 | Issue 9 | Year September-2018
DOI (Digital Object Identifier):
Page No: 713-721
Country: EAST GODAVARI, ANDHARA PRADESH, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002926

Print This Page

Current Call For Paper

Jetir RMS