UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 9
September-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1809436


Registration ID:
188561

Page Number

214-220

Share This Article


Jetir RMS

Title

Orthodontic wires of Ni-Cr and Ni-Ti alloys and its corrosion resistance in the absence and presence of Ciprofloxacin Hydrochloride tablet 500mg in artificial saliva

Abstract

ABSTRACT Orthodontic wires of Ni-Cr and Ni-Ti alloys and its corrosion resistance in the absence and presence of Ciprofloxacin Hydrochloride tablet 500mg in artificial saliva has been evaluated by electrochemical study such as AC impedance spectroscopy. This electrochemical study has been used to investigate the corrosion behaviour of these alloys. The analysis of the protective film formed on the metal surface was done using AC impedance spectra. In presence of Ciprofloxacin Hydrochloride tablet in Artificial saliva, the corrosion resistance of Ni-Ti alloy is increases and Ni-Cr alloy is decreases. This is Evidenced by increases of Charge transfer resistance (Rct),decreases of double layer capacitance (Cdl) in Ni-Ti alloy and decreases of Charge transfer resistance (Rct),increases of double layer capacitance (Cdl) in Ni-Cr alloy. The high corrosion resistance of Ni-Ti alloy is due to the formation of a protective film on the metal surface. This protective film confirmed that the active principles of the tablet ingredients have co-ordinated with the Ni-Ti metal ions through their polar atoms to form a complex. The low corrosion resistance of Ni-Cr alloy is due to the absence of the protective film on the metal surface. Hence these electro chemical studies conclude that people clipped with orthodontic wire made of Ni-Ti alloy can take Ciprofloxacin Hydrochloride (500mg) tablet orally without any hesitation. But in the case of Ni-Cr alloy, People should avoid taking Ciprofloxacin Hydrochloride tablet orally while they are clipping the orthodontic wire made of Ni-Cr alloy.

Key Words

: Corrosion resistance, AC impedance spectra, orthodontic wire, Ciprofloxacin Hydrochloride, Ni-Cr and Ni-Ti alloys.

Cite This Article

"Orthodontic wires of Ni-Cr and Ni-Ti alloys and its corrosion resistance in the absence and presence of Ciprofloxacin Hydrochloride tablet 500mg in artificial saliva ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 9, page no.214-220, September-2018, Available :http://www.jetir.org/papers/JETIR1809436.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Orthodontic wires of Ni-Cr and Ni-Ti alloys and its corrosion resistance in the absence and presence of Ciprofloxacin Hydrochloride tablet 500mg in artificial saliva ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 9, page no. pp214-220, September-2018, Available at : http://www.jetir.org/papers/JETIR1809436.pdf

Publication Details

Published Paper ID: JETIR1809436
Registration ID: 188561
Published In: Volume 5 | Issue 9 | Year September-2018
DOI (Digital Object Identifier):
Page No: 214-220
Country: Dindigul,Dindigul(Dt), Tamil Nadu, India .
Area: Chemistry
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002853

Print This Page

Current Call For Paper

Jetir RMS