TRIBOLOGICAL BEHAVIOR OF Al2O3-TiO2 COATED Ti6Al4V IMPLANT ALLOY IN SIMULATED BODY ENVIRONMENT

Abstract

Ti6Al4V alloys are extensively used in medical applications due to their superior mechanical properties. But, Ti6Al4V alloys are poor in tribological properties such as wear and corrosion resistance. Poor wear resistance leads to formation of wear debris in human implants and causes inflammation. In this work, Al2O3-TiO2 coating is applied to improve the wear and corrosion resistance. Al2O3-TiO2 coating was deposited on the substrate with 100µm, 200µm , 300µm , 400µm thickness using detonation spray(DS). Implants are lies inside the human body; Hence wear, surface roughness and corrosion behavior was studied in the simulated body environment using Hank’s solution. ASTM G-99 standard specimens are used for pin on disc wear tests. Experiments are carried out using Taguchi design. Grey relational analysis and response surface method are used for obtaining optimal experimental parameters. Improvement was observed in wear resistance for the Al2O3-TiO2 coated Ti6Al4V alloy.

Key Words

Detonation spray, Hank’s solution, Wear, Corrosion, Taguchi Method, Grey relational analysis

Cite This Article

"TRIBOLOGICAL BEHAVIOR OF Al2O3-TiO2 COATED Ti6Al4V IMPLANT ALLOY IN SIMULATED BODY ENVIRONMENT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 9, page no.531-537, September-2018, Available :http://www.jetir.org/papers/JETIR1809483.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"TRIBOLOGICAL BEHAVIOR OF Al2O3-TiO2 COATED Ti6Al4V IMPLANT ALLOY IN SIMULATED BODY ENVIRONMENT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 9, page no. pp531-537, September-2018, Available at : http://www.jetir.org/papers/JETIR1809483.pdf

Publication Details

Published Paper ID: JETIR1809483
Registration ID: 188743
Published In: Volume 5 | Issue 9 | Year September-2018
DOI (Digital Object Identifier):
Page No: 531-537
Country: Visakhapatnam, Andhra Pradesh, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002973

Print This Page

Current Call For Paper

Jetir RMS