UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 12
December-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1812243


Registration ID:
192961

Page Number

296-301

Share This Article


Jetir RMS

Title

Optimization of High Voltage Electrodes for Post Insulators used in 400kV Transmission System

Abstract

: Insulators for Extra High Voltages (EHV), exceeding 200 kV, may have grading rings installed at their terminals. The design and testing of the HV electrodes (Corona rings, Bus conductors etc.) is most important because high voltage fields affect the performance of equipments with regard to voltage stresses near the HV ends and also influence the voltage distribution. This paper describes the optimization of electric field and potential distribution along Station post insulators of rating 420kV. A number of different corona ring geometries were compared. The effect of changing ring diameter, overall diameter and placement along the insulator were investigated. Modelling and simulation of high voltage electrodes for the EHV bus post insulators is done by using coulomb 3D software, which used Boundary Element Method (BEM). The results of the simulation studies, carried out to optimize the High Voltage Electrodes (Corona rings, Bus conductors etc.) geometries that have to be provided at the live end of 400kV station post insulators, are presented. The corona onset gradients for the various configurations of the Grading ring were calculated and compared with the maximum gradients obtained in the simulation studies. .

Key Words

Cite This Article

"Optimization of High Voltage Electrodes for Post Insulators used in 400kV Transmission System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 12, page no.296-301, December-2018, Available :http://www.jetir.org/papers/JETIR1812243.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Optimization of High Voltage Electrodes for Post Insulators used in 400kV Transmission System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 12, page no. pp296-301, December-2018, Available at : http://www.jetir.org/papers/JETIR1812243.pdf

Publication Details

Published Paper ID: JETIR1812243
Registration ID: 192961
Published In: Volume 5 | Issue 12 | Year December-2018
DOI (Digital Object Identifier):
Page No: 296-301
Country: HYDERABAD, TELANGANA, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002883

Print This Page

Current Call For Paper

Jetir RMS