UGC Approved Journal no 63975(19)
New UGC Peer-Reviewed Rules

ISSN: 2349-5162 | ESTD Year : 2014
Volume 12 | Issue 9 | September 2025

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 12
December-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1812732


Registration ID:
193796

Page Number

242-250

Share This Article


Jetir RMS

Title

Decoupled Adaptive Noise Detection control based Three Phase Four-Leg Grid tied PV Inverter (VSC) Using Fractional Order PID Controller

Authors

Abstract

A grid supportive two stage three phase four wire 4-Leg SPV (Solar Photovoltaic) system with Fractional Order PID controller is presented in this paper, wherein a boost converter is used as a first stage to serve the function of MPPT (Maximum Power Point Tracking) and a 4-leg VSC (Voltage Source Converter) is used to feed the extracted SPV energy along with supporting distribution system for improvement in the power quality. The elimination of harmonics, grid currents balancing and compensation for non-active part of the load currents are extra features offered by proposed system other than conventional features of the solar inverter. The true power reflecting part of load current is estimated using FOPID Based decoupled adaptive noise detection (DAND) algorithm approach. The output of which is current component reflected on grid side to instantaneously regulate the DC link voltage using proposed Fractional Order PID. In the proposed approach, the load, PV array and loss contributions are kept decoupled. The feasibility of proposed control algorithm is confirmed via MATLAB/SIMULINK results.

Key Words

Fractional Order PID (FOPID), DAND, Solar PV; Two-stage; Power Quality; MPPT.

Cite This Article

"Decoupled Adaptive Noise Detection control based Three Phase Four-Leg Grid tied PV Inverter (VSC) Using Fractional Order PID Controller ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 12, page no.242-250, December-2018, Available :http://www.jetir.org/papers/JETIR1812732.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Decoupled Adaptive Noise Detection control based Three Phase Four-Leg Grid tied PV Inverter (VSC) Using Fractional Order PID Controller ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 12, page no. pp242-250, December-2018, Available at : http://www.jetir.org/papers/JETIR1812732.pdf

Publication Details

Published Paper ID: JETIR1812732
Registration ID: 193796
Published In: Volume 5 | Issue 12 | Year December-2018
DOI (Digital Object Identifier):
Page No: 242-250
Country: -SPSR NELLORE, -ANDHRA PRADESH, --INDIA .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002953

Print This Page

Current Call For Paper

Jetir RMS