UGC Approved Journal no 63975(19)
New UGC Peer-Reviewed Rules

ISSN: 2349-5162 | ESTD Year : 2014
Volume 12 | Issue 9 | September 2025

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 2
February-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1902226


Registration ID:
197268

Page Number

207-214

Share This Article


Jetir RMS

Title

Potentiometric Determination of Cadmium using Schiff Base (MPES) as Electroactive Ionophore

Abstract

A Schiff base 5-Methoxy-N-(2-pyridylethylsulfanylethyl) salicylideneiminate (MPES) have been used for the construction of PVC based ion-selective electrode. Fixed interference method was used to determine the selectivity of the proposed electrode. The membrane components of the electrode were optimized by using different plasticizers. The membrane electrode with composition of BEHS: PVC: MPES: Anionic additive i.e. 65%:32%:2%:1% (w/w) respectively has a detection limit of 4.6 x 10-11 M in a concentration range of 2.1 x10-10 M to 1.0 x 10-1 M with a Nernstian slope of 33.5 1.0 mV/ decade of activity. The proposed membrane electrode no.7 works satisfactorily in a pH range of 1.5-6.8 with a response time of ~5s. The effect of various internal solutions, ionic and non-ionic surfactants on the potential response of the electrode was also studied.

Key Words

Cadmium, Selectivity, ion-selective electrode, Surfactant.

Cite This Article

"Potentiometric Determination of Cadmium using Schiff Base (MPES) as Electroactive Ionophore", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 2, page no.207-214, February-2019, Available :http://www.jetir.org/papers/JETIR1902226.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Potentiometric Determination of Cadmium using Schiff Base (MPES) as Electroactive Ionophore", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 2, page no. pp207-214, February-2019, Available at : http://www.jetir.org/papers/JETIR1902226.pdf

Publication Details

Published Paper ID: JETIR1902226
Registration ID: 197268
Published In: Volume 6 | Issue 2 | Year February-2019
DOI (Digital Object Identifier): http://doi.one/10.1729/Journal.19622
Page No: 207-214
Country: New Delhi, Delhi, India .
Area: Chemistry
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002984

Print This Page

Current Call For Paper

Jetir RMS