EXPERIMENT AND ANALYSIS OF COMPARISON BETWEEN STANDARD VCRS & VCRS WITH EJECTOR SYSTEM

Abstract

As we know that an expansion device is used in standard vapor compression refrigeration system between the condenser and the evaporator, due to this there are losses to be found in expansion process that is loss in kinetic energy and can also drastically affects the COP of system , here we have used an ejector which helps in recovery of the available work and due to this there is increment found in the suction pressure of compressor which has aided in improvising the COP of the system . To compare and investigate the enhancement with normal system a model with refrigerant R22 was developed and temperature versus environment graph was measured using thermocouples at the system parameters, at specific points the properties of refrigerant undergoing a change of state was obtained from ASHRAE and the temperature data was recorded at normal room temperature conditions, from this study we can have obtained the results that a normal VCRS cycle with respect to an Ejector system shows more losses . The results obtained in the calculation clearly shows the rise in COP between 10-15 %. This analysis pinpoints the performance of the compressor as well as its necessity in the conventional VCRS cycle. parametric analysis of the VCRS with ejector indicated that COP is affected directly by the temperatures of evaporator and condenser. Additionally, the rise in compressor temperature due to on-off cycle was found to be lower with respect to the former system.

Key Words

Ejector, Vapor compression refrigeration system, COP, Household refrigerator, Hermetic reciprocating compressor, thermodynamic losses, PH diagram

Cite This Article

"EXPERIMENT AND ANALYSIS OF COMPARISON BETWEEN STANDARD VCRS & VCRS WITH EJECTOR SYSTEM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 2, page no.775-783, February-2019, Available :http://www.jetir.org/papers/JETIR1902900.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"EXPERIMENT AND ANALYSIS OF COMPARISON BETWEEN STANDARD VCRS & VCRS WITH EJECTOR SYSTEM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 2, page no. pp775-783, February-2019, Available at : http://www.jetir.org/papers/JETIR1902900.pdf

Publication Details

Published Paper ID: JETIR1902900
Registration ID: 198596
Published In: Volume 6 | Issue 2 | Year February-2019
DOI (Digital Object Identifier):
Page No: 775-783
Country: Vadodara, Gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003175

Print This Page

Current Call For Paper

Jetir RMS