Abstract

In the present day and age, human implant materials are making significant strides in their application towards the biomedical sector. Human implants have piqued the interest of material and metallurgy researchers due to their unique properties. Stainless steel based human implant is widely used in orthopedic implantology, although biological complications may result from its insufficient mechanical and tribological properties. There are multiple forms of stainless steel starting with the introduction of type 302 for its application in orthopedic surgery. Type 316L stainless steel is commonly used in surgical procedures to replace biological tissue or to help stabilize a biological structure. To contribute further in the same area, the purpose of the current research work is to investigate the machinability of -SS-L107.12 (a stainless steel based human implant) using a non-traditional method called wire electrical discharge machining (WEDM). The machinability of the machining process has been evaluated based on the material removal rate, using a roughness meter and the atomic force microscope. The further impact of the machining parameters on the output responses was analyzed based on the statistical analysis.

Key Words

Human Implant Material, Titanium, Roughness, material removal rate (MRR), Machinability and Biocompatibility

Cite This Article

"Machinability and Biocompatibility Studies on Human Implant Material", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 3, page no.246-256, March-2019, Available :http://www.jetir.org/papers/JETIR1903O38.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Machinability and Biocompatibility Studies on Human Implant Material", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 3, page no. pp246-256, March-2019, Available at : http://www.jetir.org/papers/JETIR1903O38.pdf

Publication Details

Published Paper ID: JETIR1903O38
Registration ID: 511712
Published In: Volume 6 | Issue 3 | Year March-2019
DOI (Digital Object Identifier):
Page No: 246-256
Country: HANDWARA, Jammu and Kashmir, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000158

Print This Page

Current Call For Paper

Jetir RMS