UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 4
April-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1904889


Registration ID:
206009

Page Number

588-596

Share This Article


Jetir RMS

Title

PARAMETRIC STUDY ON EFFECT OF WIND LOAD ON TALL BUILDING WITH AND WITHOUT INFILL WALL BY CONSIDERING EQUIVALENT DIAGONAL STRUT

Abstract

Designs of tall buildings for wind loads are mainly dependent upon standard wind codes which are very limited as, considering surrounding buildings arrangement is very complicated. Wind loading codes are developed from different wind tunnel tests of isolated buildings for different topography conditions and wind environments. When the interference effects (IF) of neighbouring buildings are considered, the wind tunnel tests must require and interference factor should be found out. Neighbouring structure influences the wind induced forces on a building by increasing or decreasing the forces. Here, in this paper attempt has been made to study wind interference effect on tall building by using available experimental results. The masonry infill walls influence greatly the response of the RC structures under lateral loading due to their contribution to strength and stiffness. In this study, the equivalent diagonal strut model is considered. The basic parameter of this strut is its equivalent width. By providing diagonal strut as infill wall it has been shown that it increases the stiffness of building under lateral load.

Key Words

tall building, wind interference effect, infill wall, equivalent diagonal strut.

Cite This Article

"PARAMETRIC STUDY ON EFFECT OF WIND LOAD ON TALL BUILDING WITH AND WITHOUT INFILL WALL BY CONSIDERING EQUIVALENT DIAGONAL STRUT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 4, page no.588-596, April-2019, Available :http://www.jetir.org/papers/JETIR1904889.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"PARAMETRIC STUDY ON EFFECT OF WIND LOAD ON TALL BUILDING WITH AND WITHOUT INFILL WALL BY CONSIDERING EQUIVALENT DIAGONAL STRUT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 4, page no. pp588-596, April-2019, Available at : http://www.jetir.org/papers/JETIR1904889.pdf

Publication Details

Published Paper ID: JETIR1904889
Registration ID: 206009
Published In: Volume 6 | Issue 4 | Year April-2019
DOI (Digital Object Identifier):
Page No: 588-596
Country: DEVGADH BARIA, Gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002872

Print This Page

Current Call For Paper

Jetir RMS