COMPARATIVE STUDY OF IN-SITU LONG PILE FROM BI-DIRECTIONAL STATIC LOAD TEST: A CASE STUDY AT VISHAKHAPATNAM

Abstract

Bi-directional static loading test adopting load cells is widely used around the world at present, with increase in diameter and length of deep foundations. Some new load cells, test procedure, and construction technology were adopted based on the applications to different deep foundations. The paper presents the results of the bi-directional static load testing of a 1200mm diameter bored pile was designed for a load of 450 tons using a single level of S-cell. The length of the pile is 56.225m. The bi-directional static load testing method has proved advantageous over the conventional pile load testing methods in many aspects. This case was analyzed using finite element program PLAXIS 2D. The self-weight of the upper pile segment was taken into acccount. The equivalent top-load curve is used to illustrate as if the pile loaded from the pile head such as conventional head-down test. Comparison are presented between the results obtained when analyzed in PLAXIS and when field test is done.

Key Words

Bi-directional load test, Cast in situ pile, Super cell, Ultimate bearing capacity

Cite This Article

"COMPARATIVE STUDY OF IN-SITU LONG PILE FROM BI-DIRECTIONAL STATIC LOAD TEST: A CASE STUDY AT VISHAKHAPATNAM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 4, page no.289-294, April-2019, Available :http://www.jetir.org/papers/JETIR1904F49.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"COMPARATIVE STUDY OF IN-SITU LONG PILE FROM BI-DIRECTIONAL STATIC LOAD TEST: A CASE STUDY AT VISHAKHAPATNAM", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 4, page no. pp289-294, April-2019, Available at : http://www.jetir.org/papers/JETIR1904F49.pdf

Publication Details

Published Paper ID: JETIR1904F49
Registration ID: 206441
Published In: Volume 6 | Issue 4 | Year April-2019
DOI (Digital Object Identifier):
Page No: 289-294
Country: SABARKANTHA, GUJARAT, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002840

Print This Page

Current Call For Paper

Jetir RMS