UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 4
April-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1904N10


Registration ID:
207754

Page Number

52-58

Share This Article


Jetir RMS

Title

Development and Validation of New RP-HPLC Method for the Determination of Alogliptin Benzoate in Bulk Form and Dosage Form

Abstract

: Chromatography was performed by isocratic reverse phase separation using an Agilent Eclipse plus C18 column of particle size 5µ, (150×4.6mm). The separations were achieved at the UV detection of 276nm using the mobile phase of Phosphate buffer: Methanol in the ratio of 60:40. Flow rate was 1ml/min and the injection volume was set at 20 µl with 10mins of runtime. The retention time was observed at 4.4 mins for Alogliptin benzoate. The method was validated by using various validation parameters like accuracy, precision, linearity, limit of detection (LOD), limit of quantification (LOQ). The standard curve was linear over a working range of 5-30 µg/ml and gave an average correlation factor 0.999. The limit of detection and the limit of quantification were found to be 0.55µg/ml and 1.86µg/ml respectively. The method showed good recoveries and relative standard deviations of intra and inter day assay less than 2. This method can be easily and conveniently used for routine analysis of Alogliptin in bulk and tablet dosage forms

Key Words

Alogliptin benzoate, RP-HPLC, Accuracy, Precision, Linearity, LOD, LOQ.

Cite This Article

"Development and Validation of New RP-HPLC Method for the Determination of Alogliptin Benzoate in Bulk Form and Dosage Form", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 4, page no.52-58, April-2019, Available :http://www.jetir.org/papers/JETIR1904N10.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Development and Validation of New RP-HPLC Method for the Determination of Alogliptin Benzoate in Bulk Form and Dosage Form", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 4, page no. pp52-58, April-2019, Available at : http://www.jetir.org/papers/JETIR1904N10.pdf

Publication Details

Published Paper ID: JETIR1904N10
Registration ID: 207754
Published In: Volume 6 | Issue 4 | Year April-2019
DOI (Digital Object Identifier):
Page No: 52-58
Country: Bangalore, Karnataka, India .
Area: Pharmacy
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002858

Print This Page

Current Call For Paper

Jetir RMS