Abstract
Analysis and Design of Intze Type Water Tank
Ankita D. Katkar1 , Sanjay k Bhadke2
Dept.of civil engineering,
Tulsiramji Gaikwad-Patil College of Engineering & Technology
Nagpur, Maharashtra, India
9921115057
ankikatkar95@gmail.com
Abstract— Water is life line for every kind of creature in this world. All around the world liquid storage tanks are used extensively by municipalities and industries for water supply, fire fighting systems, inflammable liquids and other chemicals. Thus Water tanks plays a vital role for public utility as well as industrial structure having basic purpose to secure constant water supply from longer distance with sufficient static head to the desired location under the effect of gravitational force. In such situations elevated water tanks become an important part of life. According to seismic code IS 1893(Part-1):2000, more than 60% of India is prone to earthquakes. The analysis was conducted as per the specifications of IS 3370, IS 800:2002, IS 875, IS 1893. Design of tank by the dome, Ring beam supporting the dome, Cylindrical walls, Ring beam at the junction of the cylindrical walls and the conical wall , Conical slab, Floor of the tank, The ring girder, Columns, Tower with bracings, Foundations as per IS 3370 -Part III will be done by using 2-Dimensional STAAD model for different 2,50,000 Litres capacity tank . Different loads such as Dead Load, Live Load, Wind load, Earthquake Load will be applied on STAAD model at appropriate location as per codes used for Loading. All the results obtain from STADD are compared with the help of Excel sheets. With the standard dimensions of the Intze reservoir to be modeled be safe for wind loads, seismic loads etc.