TIME HISTORY ANALYSIS OF IRREGULAR RC BASE ISOLATED STRUCTURE WITH AND WITHOUT MASONRY INFILL

Abstract

This article presents an outline of the base isolation techniques with special emphasis for reducing earthquake forces on the structures. The effects of base isolation on structures are briefly discussed. Base isolation is an anti-seismic design strategy that can reduce the effect of earthquake ground motion by isolating the superstructure from the foundation. The important feature of the base isolation technique is that it introduces flexibility to the structure. In this present study, a G+9 storey RC irregular structure is considered and dynamic analysis has been carried out by Time History analysis using ETABS V15.1 software as per IS-1893:2002(Part-I). The lead rubber bearing is used as the seismic isolation device which is provided at the base of the structure and the masonry infills are modelled as compression diagonal struts which are assumed to be pin-jointed at both ends. Equivalent diagonal strut method was considered to design the masonry struts as per IS-1893:2016(Part-I). For the Time History analysis BHUJ earthquake ground motion records was considered. This present study tends to demonstrates how the structure efficiency can be influenced by providing seismic isolation system and how the masonry infills behave as a constituent part of the structural system in seismic events. The performance of building will be evaluated on the basis of seismic parameters like storey displacement, time period, inter-storey drifts and base shear.

Key Words

Cite This Article

"TIME HISTORY ANALYSIS OF IRREGULAR RC BASE ISOLATED STRUCTURE WITH AND WITHOUT MASONRY INFILL", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.444-453, June-2019, Available :http://www.jetir.org/papers/JETIR1906354.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"TIME HISTORY ANALYSIS OF IRREGULAR RC BASE ISOLATED STRUCTURE WITH AND WITHOUT MASONRY INFILL", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp444-453, June-2019, Available at : http://www.jetir.org/papers/JETIR1906354.pdf

Publication Details

Published Paper ID: JETIR1906354
Registration ID: 214384
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier): http://doi.one/10.1729/Journal.21143
Page No: 444-453
Country: Bangalore, Karnataka, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002833

Print This Page

Current Call For Paper

Jetir RMS