UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 6
June-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1906550


Registration ID:
212020

Page Number

763-767

Share This Article


Jetir RMS

Title

ENERGY AUDIT AT ABOO BAKER ICE PLANT

Abstract

Energy demand keeps rising day by day so that it is essential to decrease the amount of energy consumption for that energy audit is needed. For conservation of energy the best option is energy audit. EA is the process of when, where, why and how the energy is used in a plant or building. Normally, energy auditing is carried out and performed by certified energy auditors and energy managers. By conducting energy audit process in industry, employees try to conserve the energy in day-to-day action. This project determines to find out cooling load estimation in Aboo baker ice plant, Ratnagiri. The main goal and objective of this project is to give and make available ways to decrease energy utilization and consumption per unit of product output so as to decrease operating cost. A well-known cooling load calculation and estimation procedure has been adopted and utilise by American Society of Heating, Refrigeration and Air conditioning Engineering, used in this project to predict the cooling load added due to types of wall, windows, roofs, infiltration, calculation of all parameters and heat loads hence to give them a better solution. Results of these calculations could be used to implement the type of system into the company. Calculation of cooling load is estimated using ASHRAE handbook procedure and the agreement was found to be unsatisfactory. Cooling load per TR is more compared to other ice plant hence we gave them a better solution/suggestion to implement the system into the company.

Key Words

Ice plant, Energy audit, Cooling load, ISHRAE.

Cite This Article

"ENERGY AUDIT AT ABOO BAKER ICE PLANT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.763-767, June-2019, Available :http://www.jetir.org/papers/JETIR1906550.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"ENERGY AUDIT AT ABOO BAKER ICE PLANT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp763-767, June-2019, Available at : http://www.jetir.org/papers/JETIR1906550.pdf

Publication Details

Published Paper ID: JETIR1906550
Registration ID: 212020
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 763-767
Country: Ratnagiri., Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002870

Print This Page

Current Call For Paper

Jetir RMS