ISLANDING DETECTION TECHNIQUE FOR INVERTER BASED DISTRIBUTED GENERATOR USING REACTIVE POWER DISTURBANCES

Abstract

In this paper, an islanding recognition strategy for inverter-based distributed generators (DGs) is presented, which is based on irritating reactive power yield. Two sets of disturbances are designed in this strategy, which have distinctive amplitudes and length time. The first set of reactive power disturbance (FSORPD) is occasional with small amplitudes to break the reactive power adjust amid islanding, whereas the greatness of the second set of reactive power disturbance (SSORPD) is sufficient to constrain the recurrence to stray outside its threshold limits. Considering all the possible recurrence variety characteristics with the FSORPD in the wake of islanding, three criterions are designed for switching the disturbance from the FSORPD to the SSORPD. Since DGs situated at various positions have the same recurrence variety characteristics, the SSORPDs can be included distinctive DGs at the same time without the need of correspondence. In this manner, synchronization of the SSORPDs can be ensured for the system with different DGs and the technique can distinguish islanding with a zero no detection zone property. In addition, the strategy can be connected to the DG either working at solidarity power factor or supplying reactive power as well for its neighbourhood load.

Key Words

ISLANDING DETECTION TECHNIQUE FOR INVERTER BASED DISTRIBUTED GENERATOR USING REACTIVE POWER DISTURBANCES

Cite This Article

"ISLANDING DETECTION TECHNIQUE FOR INVERTER BASED DISTRIBUTED GENERATOR USING REACTIVE POWER DISTURBANCES", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.594-603, June 2019, Available :http://www.jetir.org/papers/JETIR1906O82.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"ISLANDING DETECTION TECHNIQUE FOR INVERTER BASED DISTRIBUTED GENERATOR USING REACTIVE POWER DISTURBANCES", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp594-603, June 2019, Available at : http://www.jetir.org/papers/JETIR1906O82.pdf

Publication Details

Published Paper ID: JETIR1906O82
Registration ID: 217052
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 594-603
Country: -, -, - .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002851

Print This Page

Current Call For Paper

Jetir RMS