Seismic Analysis of Symmetrical and Unsymmetrical Multistory Building with Shear Wall and Hybrid Shear Wall

Abstract

Shear walls are structural systems which provide stability to structures from lateral loads like wind, seismic load. Shear walls are added to the building interior to provide more strength and stiffness to the building when the exterior walls cannot provide enough strength and stiffness. It is necessary to provide these shear walls when the tolerable span width ratio for the floor or roof diaphragm is exceeded. Shear walls are mainly flexural members and usually is provided in high- and low-rise buildings to avoid the total collapse of buildings under seismic forces. In this paper 10 storey symmetrical and unsymmetrical building in zone II is consider and analyzed by comparing result obtain by changing various location of shear wall and hybrid shear wall. Analysis is performed to study effect of shear wall location on story drift, displacement and base shear. Analysis is done using ETABs software.

Key Words

Hybrid Shear Wall, Response Spectrum Analysis, ShearWall, Seismic Forces.

Cite This Article

"Seismic Analysis of Symmetrical and Unsymmetrical Multistory Building with Shear Wall and Hybrid Shear Wall", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.433-444, June 2019, Available :http://www.jetir.org/papers/JETIR1906T50.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Seismic Analysis of Symmetrical and Unsymmetrical Multistory Building with Shear Wall and Hybrid Shear Wall", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp433-444, June 2019, Available at : http://www.jetir.org/papers/JETIR1906T50.pdf

Publication Details

Published Paper ID: JETIR1906T50
Registration ID: 218558
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 433-444
Country: AURANGABAD, OPPOSITE KANDI HOSTEL , BHAJIWALI BAI STATUE, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002799

Print This Page

Current Call For Paper

Jetir RMS