UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 6
June-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1907958


Registration ID:
220970

Page Number

505-510

Share This Article


Jetir RMS

Title

A SIMPLE OPEN CIRCUIT DETECTION STRATEGY FOR A SINGLE PHASE 7 LEVEL GRID CONNECTED CASCADED H-BRIDGE MULTI-LEVEL INVERTER FED FROM POWER OPTIMIZERS.

Abstract

In the present work, a single-phase grid-connected photo voltaic inverter is supplied by series-connected power optimizer (POs); a straightforward and real-time open-circuit fault (OCF) detection technique is suggested. PO controllers periodically track differences in output voltage of power optimizer and calculate remaining mistakes in output voltage to implement the suggested technique. Then, on the PO side, the inverters OCF identification rule is developed based on the voltage variation amount and the improved judgment criterion derived from residual voltage error and power. The proposed method for detecting open circuit fault (OCF) is low cost and real time, requiring no additional hardware and no communication between the inverter and power optimizers (PO).Generally speaking, in series-connected distributed DC power or energy storage systems, the technique offers a reliable and quick solution to detect OCFs. Experimental results verify its efficiency and reliability. The circuit simulation is carried out in MATLAB/SIMULINK it is seen that the total harmonic distortion (THD) is reduced and is less than 6% which agrees with IEEE Standards. The experimental results are in good agreement with the simulation results and thus the model is validated.

Key Words

Inverter, Open-circuit fault (OCF), Grid-connected photo voltaic (PV) system, Power optimizer (PO), Maximum power point (MPP) & Total harmonic distortion (THD).

Cite This Article

"A SIMPLE OPEN CIRCUIT DETECTION STRATEGY FOR A SINGLE PHASE 7 LEVEL GRID CONNECTED CASCADED H-BRIDGE MULTI-LEVEL INVERTER FED FROM POWER OPTIMIZERS.", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.505-510, June 2019, Available :http://www.jetir.org/papers/JETIR1907958.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"A SIMPLE OPEN CIRCUIT DETECTION STRATEGY FOR A SINGLE PHASE 7 LEVEL GRID CONNECTED CASCADED H-BRIDGE MULTI-LEVEL INVERTER FED FROM POWER OPTIMIZERS.", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp505-510, June 2019, Available at : http://www.jetir.org/papers/JETIR1907958.pdf

Publication Details

Published Paper ID: JETIR1907958
Registration ID: 220970
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 505-510
Country: Bengaluru, Karnataka, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002805

Print This Page

Current Call For Paper

Jetir RMS