UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 6
June-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1908373


Registration ID:
225697

Page Number

469-474

Share This Article


Jetir RMS

Title

Structural Audit and Repair of Commercial Building

Abstract

Structural Audit is an overall health and performance medical examination of a building like a doctor examines a patient. It ensures that the building and its premises are safe and don't have any risk. It analyses and suggests acceptable repairs and retrofitting measures needed for the buildings to perform better in its service life. The project is to detect the faults and the problems which are likely to cause threat to the building structure. The visual inspection is done to detect the visual cracks in columns, beams, slabs and walls of any sign of deterioration. The other methods are Destructive and Non-destructive testing method (NDT). In this project we are auditing the structure by Non-destructive testing method, in which it includes Rebound hammer test, Ultra sonic pulse velocity test and Half-cell test; in Ultra sonic test we performed it for columns C1, C2, C3, etc. After examining the defects and faults of the structure, we have to prevent for deterioration with special repairing methods. The method used in our project for repairing are Grouting for filling up the cracks, slab strengthening by micro concrete, jacketing for beams and column, waterproofing of terrace slab and plastering work for walls. Different suitable materials were used for different methods of repairing such as micro concrete which is one type of non-shrinkage material used as concrete in strength of slab and jacketing, cement motar (1:6) for plastering, etc. Therefore the above methods are used and reading of NDT are carried out before and after repair for better understanding of change in strength after repair. Also the estimated material cost for repairing work is calculated.

Key Words

Non-destructive testing, Grouting, jacketing

Cite This Article

"Structural Audit and Repair of Commercial Building ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.469-474, June 2019, Available :http://www.jetir.org/papers/JETIR1908373.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Structural Audit and Repair of Commercial Building ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp469-474, June 2019, Available at : http://www.jetir.org/papers/JETIR1908373.pdf

Publication Details

Published Paper ID: JETIR1908373
Registration ID: 225697
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 469-474
Country: Mumbai, maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002816

Print This Page

Current Call For Paper

Jetir RMS