Study of the Reniforced Concrete Frame With Bricks Masonry

Abstract

In the building construction, framed structures are frequently used due to ease of construction and rapid progress of work. Masonry infill panels have been widely used as interior and exterior partition walls for aesthetic reasons and functional needs. When infill walls are omitted in a particular storey, a soft storey is formed compared to much stiffer other stories. The masonry infill has been modeled by equivalent struts. Normally in structural analysis it is considered that the Equivalent Static Analysis is more conservative against ground shaking for regular structures or structures of smaller height. In this paper the behavior of reinforced concrete (R.C.) frames with brick masonry infill for various parametric changes have been studied to observe their influences in deformation patterns of the frame. The present study is also aimed at findings out the effect of soft storey on frame structures due to horizontal loading. In both cases of wind and earthquake loads, if number of bay increases, then the deflection eventually decreases. As the story level of a building frame increases, deflection due to lateral loads naturally increases due to additional lateral loads. Deflection increases linearly if the span of bay increases linearly because of linearly increased loads. Deflection for a soft storey building frame is 1.4 to 2.0 times greater than that observed excluding the soft storey effect. Deflection for R.C. frames with 5 inch wall thickness is observed 10 to 20% higher than that for frames with 10 inch wall thickness.

Key Words

infill, soft story, Equivalent Static Analysis, equivalent struts, Saneinejad Theory, Mainstone.

Cite This Article

" Study of the Reniforced Concrete Frame With Bricks Masonry ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.168-169, June-2019, Available :http://www.jetir.org/papers/JETIR1908964.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

" Study of the Reniforced Concrete Frame With Bricks Masonry ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp168-169, June-2019, Available at : http://www.jetir.org/papers/JETIR1908964.pdf

Publication Details

Published Paper ID: JETIR1908964
Registration ID: 226486
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 168-169
Country: chhindwara, M.P., India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002967

Print This Page

Current Call For Paper

Jetir RMS