UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 10 | October 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 7 Issue 6
June-2020
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2006327


Registration ID:
234380

Page Number

2262-2267

Share This Article


Jetir RMS

Title

Seismic analysis of mass irregular structure of high rise building at different floor area with and without shear wall at different location

Abstract

In the current scenario, population is rising day by day. High rise buildings are very much needed to meet the needs of the population. The high elevation buildings are designed to withstand the forces of the earthquake. It is said that a typical structure has uniform mass, stiffness, strength and structural form. The response to earthquake forces of a normal system is predictable. The behavior of an irregular structure to earthquake forces is unpredictable due to mass irregularity, irregularity of torsion, weak storey, discontinuity of the diaphragm, etc. Now for convenience of people mass differ in different floor location in building due to new parking systems, swimming pool, machinery (such as gym machinery) etc.. The shear wall provides the lateral strength required to withstand horizontal forces from the earthquake. Initially Building with various heights such as G+9 and G+14 is modelled which have mass irregularity in every 5th floor with different shear wall are applied and analyzed for Seismic Zone IV and V with the help of ETABS. Result of different models shows the response parameters and its difference are compared graphically to determine behavior of structure.

Key Words

- Shear wall at outer side, Shear wall at core, mass irregularity, Response Spectrum, Time History, Etabs

Cite This Article

"Seismic analysis of mass irregular structure of high rise building at different floor area with and without shear wall at different location", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 6, page no.2262-2267, June-2020, Available :http://www.jetir.org/papers/JETIR2006327.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Seismic analysis of mass irregular structure of high rise building at different floor area with and without shear wall at different location", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 6, page no. pp2262-2267, June-2020, Available at : http://www.jetir.org/papers/JETIR2006327.pdf

Publication Details

Published Paper ID: JETIR2006327
Registration ID: 234380
Published In: Volume 7 | Issue 6 | Year June-2020
DOI (Digital Object Identifier):
Page No: 2262-2267
Country: bhuj-kutch, gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003124

Print This Page

Current Call For Paper

Jetir RMS