Title

Implementation of Efficient Autorecloser Scheme in 132 kV Transmission System

Abstract

Whenever fault occurs on overhead transmission lines, immediate tripping of the circuit breakers isolates the fault. However, reclosing of protective relaying is essential in high voltage transmission system (above 132 kV voltage level), due to the fact that 70-80% of total faults occurring on transmission system are temporary in nature. When such temporary fault occurs, it is necessary to restore the system to its normal state to improve service continuity. Hence, it is necessary to analyze the effect of auto-reclosing scheme on overhead High Voltage (HV) transmission line. The remaining 20% – 30% of faults are permanent in nature which does not clear upon tripping and reclosing. In this situation, the auto-reclosure scheme should be blocked. This project describes new algorithm for coordination of protective relay and auto-reclosing scheme used in HV transmission line. The simulation of 132 kV transmission system along with relay modeling has been carried out in MATLAB/SIMULINK software package. The proposed scheme recloses the transmission line during transient faults and blocks/lockout the scheme during permanent faults. The results of simulation show the effectiveness of the proposed scheme in terms of both speed and reliability.

Key Words

autorecloser, power system, transmission system

Cite This Article

"Implementation of Efficient Autorecloser Scheme in 132 kV Transmission System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.8, Issue 1, page no.1095-1103, January-2021, Available :http://www.jetir.org/papers/JETIR2101137.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Implementation of Efficient Autorecloser Scheme in 132 kV Transmission System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.8, Issue 1, page no. pp1095-1103, January-2021, Available at : http://www.jetir.org/papers/JETIR2101137.pdf

Publication Details

Published Paper ID: JETIR2101137
Registration ID: 305098
Published In: Volume 8 | Issue 1 | Year January-2021
DOI (Digital Object Identifier):
Page No: 1095-1103
Country: Mehsana, Gujarat, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003088

Print This Page

Current Call For Paper

Jetir RMS