Seismic Analysis of G+5 Building Using Water Tank as Tuned Liquid Damper

Abstract

Using water tanks at roof as counteraction solutions, which are known as Tuned Liquid Dampers (TLD), in this paper six story building is considered. TLD is modelled by using Etabs 2016 software for a regular (G+5) storied OMRF building. Linear analysis performed using Time History Analysis (THA) for the records of Elcentro earthquake (1940) has been carried out. The project has been study to identify the effective of Tuned Liquid Damper(TLD). TLD can be used to control the horizontal vibration in building structures. A Tuned liquid damper is a tank filled with water, TLD is usually placed on the top of the structure nad whenever there is horizontal vibration occurs due to seismic forces that uses the sloshing energy of the water to reduce the effect vibration structure of the system when it is subjected to excitation . Water storage tank designed as to gain its natural frequency same as that of building. As a result the resonant phenomenon will occurs and give contribution to balance the building. A tuned Liquid Damper is a passive control device that dissipates the excitation energy through the boundary layer friction, liquid free surface contamination, and wave breaking.

Key Words

Tuned liquid damper, TLD, seismic protection system, sloshing.

Cite This Article

"Seismic Analysis of G+5 Building Using Water Tank as Tuned Liquid Damper", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.8, Issue 8, page no.f148-f161, August-2021, Available :http://www.jetir.org/papers/JETIR2108620.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Seismic Analysis of G+5 Building Using Water Tank as Tuned Liquid Damper", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.8, Issue 8, page no. ppf148-f161, August-2021, Available at : http://www.jetir.org/papers/JETIR2108620.pdf

Publication Details

Published Paper ID: JETIR2108620
Registration ID: 314594
Published In: Volume 8 | Issue 8 | Year August-2021
DOI (Digital Object Identifier):
Page No: f148-f161
Country: JAGDALPUR, Chhattisgarh, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000579

Print This Page

Current Call For Paper

Jetir RMS