Title

Dose mapping for Performance Qualification of Electron Beam Sterilization Facility using B3 Riso Scan Dosimetry System

Authors

Abstract

Dose mapping exercises for Performance Qualification( PQ) are used to identify locations and magnitudes of minimum and maximum doses within the product and to show the relationship between these doses and the dose at a monitoring position. This experiment was performed at 10 MeV/ 10kW electron beam accelerator which is operating in institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland. In this experiment, the acceptable dose for medical device sterilization 28kGy is applied B3 films and the dose was read out by B3 Risø Scan system. From the absorbed dose measurements, Dmin is 24.3 kGy and Dmaxis 35.8kGy.The overall dose received in container is 88.5 % to 136%. Dose Uniformity Ratio DUR is 1.4.

Key Words

Dose mapping, electron beam sterilizaition, B3 Riso scan

Cite This Article

"Dose mapping for Performance Qualification of Electron Beam Sterilization Facility using B3 Riso Scan Dosimetry System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.8, Issue 9, page no.e595-e596, September-2021, Available :http://www.jetir.org/papers/JETIR2109473.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Dose mapping for Performance Qualification of Electron Beam Sterilization Facility using B3 Riso Scan Dosimetry System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.8, Issue 9, page no. ppe595-e596, September-2021, Available at : http://www.jetir.org/papers/JETIR2109473.pdf

Publication Details

Published Paper ID: JETIR2109473
Registration ID: 315472
Published In: Volume 8 | Issue 9 | Year September-2021
DOI (Digital Object Identifier):
Page No: e595-e596
Country: Naypyitaw, Mandalay, Myanmar .
Area: Science & Technology
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000497

Print This Page

Current Call For Paper

Jetir RMS