METHOD DEVELOPMENT AND VALIDATION OF AN LCMS/MS METHOD FOR QUANTIFICATION OF TIVOZANIB IN RABBIT PLASMA

Abstract

An easy, quick, precise, active and reproducible LC-MS/MS technique was developed for the bio analytical method of Tivozanib with D4-Tivozanib as internal standard. Separation was carried on Symmetry C18 column (150 mm x 4.6mm, 3.5µm) using a isocratic elution with a buffer containing Hexane sulphonic acid and Acetonitrile in the ratio of 40:60 as mobile phase with 1mL/min flow rate at ambient temperature . Analysis was carried out within 5 minutes over a good linear concentration range from 50 ng/mL to 400 ng/mL (r2 = 0.9996) for Tivozanib. Precision and recovery study results are within the acceptable limit. This method has been successfully applied, exploring Tivozanib with its internal standard (D4-Tivozanib) was extracted from rat plasma using liquid -liquid extraction. This strategy was applied for Freeze thaw, auto sampler, bench top and long-term stability studies, we found that the drugs were stable throughout the stability studies according to USFDA guidelines.

Key Words

LC-MS/MS, Tivozanib, Rabbit plasma

Cite This Article

"METHOD DEVELOPMENT AND VALIDATION OF AN LCMS/MS METHOD FOR QUANTIFICATION OF TIVOZANIB IN RABBIT PLASMA", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 1, page no.b1-b7, January-2022, Available :http://www.jetir.org/papers/JETIR2201101.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"METHOD DEVELOPMENT AND VALIDATION OF AN LCMS/MS METHOD FOR QUANTIFICATION OF TIVOZANIB IN RABBIT PLASMA", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 1, page no. ppb1-b7, January-2022, Available at : http://www.jetir.org/papers/JETIR2201101.pdf

Publication Details

Published Paper ID: JETIR2201101
Registration ID: 317979
Published In: Volume 9 | Issue 1 | Year January-2022
DOI (Digital Object Identifier):
Page No: b1-b7
Country: Vissannapeta, AP, India .
Area: Pharmacy
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000452

Print This Page

Current Call For Paper

Jetir RMS