UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 9 Issue 2
February-2022
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2202038


Registration ID:
319816

Page Number

a305-a308

Share This Article


Jetir RMS

Title

Voltage Sag Enhancement of Grid Connection Hybrid PV-Wind Power System

Abstract

The series connected DVR will inject three-phase compensating voltages through the three-phase injection transformer or three single-phase injection transformers with the main supply. The filtered VSI output voltage is boosted to the desired level with the injection transformer. The transformer also isolates the DVR circuit from the distribution system. The capacity of the voltage source inverter (VSI) and the values for the link filter connected between the injection transformer and the inverter play a crucial in the design of the DVR. In this research project, new Dynamic Voltage Restorer (DVR) topology has been proposed. The capacity of the voltage source inverter (VSI) and values of the link filter is small that will improve the compensation capabilities for voltage harmonic, swell and voltage sag mitigation under various fault conditions. The new RLC filter is able to eliminate the switching harmonics. The capacity of the dc supply voltage is reduced when the value of inductance is small. The new DVR topology has high efficiency and the ability to improve the quality of voltage. Outline architecture of the RLC filter parameters for the specific model has been presented. The new DVR with proposed controlled Dynamic Voltage Restorer topology is modeled and simulated using the MATLAB. The control scheme has good control dynamics with minimum transient current overshoot. The simulation results under transient performance are good

Key Words

component,Superconducting magnetic energy storage (SMES); Dynamic Voltage Restorer(DVR); Voltage Sag, swell and interruption; Pulse-width modulated (PWM)

Cite This Article

"Voltage Sag Enhancement of Grid Connection Hybrid PV-Wind Power System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 2, page no.a305-a308, February-2022, Available :http://www.jetir.org/papers/JETIR2202038.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Voltage Sag Enhancement of Grid Connection Hybrid PV-Wind Power System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 2, page no. ppa305-a308, February-2022, Available at : http://www.jetir.org/papers/JETIR2202038.pdf

Publication Details

Published Paper ID: JETIR2202038
Registration ID: 319816
Published In: Volume 9 | Issue 2 | Year February-2022
DOI (Digital Object Identifier):
Page No: a305-a308
Country: Bhandara, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF