UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 9 Issue 3
March-2022
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2203271


Registration ID:
320856

Page Number

c529-c535

Share This Article


Jetir RMS

Title

EXTENSION OF FLOORS IN EXISTING R.C.C BUILDING

Abstract

This research explains the basis of the structural design process, by way of familiarizing with the requirements of the project and understanding the architectural and services concepts. This research aims at formulating the main design parameters that we will adopt in developing the structural design and detailing of the structure which will be compatible with the architectural theme, satisfy the functional needs, adhering to other applicable building norms and Indian Standards provisions to achieve a safe & stable structure. In this research the structural design to be adopted for the proposed structure covers the minimum design requirement to establish the unified design basis that will form the overall design philosophy. The design aims to achieve the following: - Structural & functional integrity. Required Structural performance under the consideration of characteristic service design loads. Design for wind and earthquakes loads. As this is an old structure the same will be checked as per latest IS standards to establish the resistance value. Structural durability & maintainability. The current state of the structure is such that if repairs required will be carried out in order to enhance its life. The possibility of adding the proposed floors and its impact on the existing building structure is the main purpose of this research. The structural health condition of the existing structure will also be studied such that improvising and strengthening procedures can be adopted as necessary, to augment the building structural health. Generally, the reverse load calculation is carried out with the help of existing structural drawings, where structural drawings are not available in such cases Non-destructive and Destructive tests are performed to find out the strength of concrete. This will give us the required information to calculate the load of the structure, determining the need (or not) to reinforce the existing structure and foundation.

Key Words

Capacity, Extension, Load Repairs, Stability, Strengthening, Structural.

Cite This Article

"EXTENSION OF FLOORS IN EXISTING R.C.C BUILDING ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 3, page no.c529-c535, March-2022, Available :http://www.jetir.org/papers/JETIR2203271.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"EXTENSION OF FLOORS IN EXISTING R.C.C BUILDING ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 3, page no. ppc529-c535, March-2022, Available at : http://www.jetir.org/papers/JETIR2203271.pdf

Publication Details

Published Paper ID: JETIR2203271
Registration ID: 320856
Published In: Volume 9 | Issue 3 | Year March-2022
DOI (Digital Object Identifier):
Page No: c529-c535
Country: Mumbai, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000367

Print This Page

Current Call For Paper

Jetir RMS